CORE ORIENTATION SYSTEMS CONTINUED Back to Product Sales  
GONIOMETER MODEL 76

To visually confirm goniometer settings, the base with the large scale should be aligned with North and placed on a stable surface (figure 1).
  1. Remove the outer strike and dip direction ring from base. Select the plastic insert to match the core size.
  2. Rotate the core holder to set "Drift Direction" of the hole (figure 2).
  3. Set the "Drift Angle" on the protractor mounted at the side of the core holder (figure 3).
  4. Align the short bent end of the drift angle pointer to the small top scale, with the same reading indicated directly below on the large scale (figure 4).
  5. To position the "Orientation Lug" rotate the double ended pointer over the small top scale to the specified azimuth reading.
  6. Place the core in the core holder. Position the Master Scribe on the core in line with the double-ended pointer. Clamp the core in position (figure 5).
THE CORE IS NOW IN A RELATIVE INSITU POSITION !!

  1. Place the outer strike and dip direction ring back on the base.
  2. Rotate and angle the sighting ring so that it appears to be a parallel extension of the planar feature to be examined.
  3. Read the "Strike" of the feature at the appropriate pointer located in a Northern quadrant on the base ring.
  4. Read "Dip Direction" at the appropriate pointer on the base ring.
  5. Read "Dip Angle" on the protractor mounted at the side of the outer strike and dip direction Ring.

Figure 1
Photographs courtesy of:
Brown, A.B., 2001, Analysis of structures in non-oriented drillcore from the Meliadine West Gold Deposit, Nunavut: Unpublished M.Sc. thesis, Laurentian University, Sudbury, Ontario, Canada.


Figure 2
The bore hole drift direction is set on the inner assembly vernier scale. This information is retrieved from the Multi-Shot survey instrument.


Figure 3
The bore hole drift angle is set on the inner assembly angular protractor. This information is retrieved from the Multi-Shot survey instrument.


Figure 4
Set the double ended pointer to the small top outer scale "Master Scribe" reading from The Mult-Shot survey data "Orientation Lug". Place the core in the core holder while aligning the master scribe to double ended pointer.


Figure 5
Place the outer strike and dip direction ring back on the base while aligning this ring so that it appears to be a parallel extension of the planar feature in the core.
International Directional Services
12030 East Riggs Road
Chandler, Arizona 85249
Tel: 480.824.7100
Fax: 480.883.2010
E-mail: idsinfo@idirectionaldrill.com

IDS HOME | HISTORY | EQUIPMENT | COST EFFECTIVE | APPLICATIONS
PRODUCT SALES | PRODUCT RENTALS | SERVICES | PROJECTS | CONTACT US

© 2009 Layne Christensen Company. All rights reserved.